BAUDRATE
0
81 B81 1 2 Baudrate for the serial port 0. (7 =
300, 6 = 600, 5 = 1200, 4 = 2400, 3 =
4800, 2 = 9600, 1 = 19200, 0 =
38400, 9 = 57600, 8 = 115200)
FLOWCON
TROL0
82 B82 1 0 Flow control for the serial port 0. (0 =
no, 1= Software XON/XOFF, 2 =
Hardware RTS/CTS)
GATEWAYD
STIP
88 B88, B89,
B90, B91
4 0.0.0.0 Serial Gateway destination IP address for
active serial gateway. If this IP address is
0.0.0.0, then the serial gateway operates in
passive (listening) mode. See also
GATEWAYPORT below.
GATEWAYP
ORT
92 W92 2 0 Serial Gateway Port. For active serial
gateway this is the destination port to
connect to (source port is random). For
passive serial gateway it's the listening
port. If the port number is 0, the serial
gateway function is completely disabled.
BOOTTAR
GET
94 W94 2 “2K” If this parameter is set to 0x0000 the
firmware with the highest version will
be started.
If this parameter is set to a value
highest version of the firmware with
this target will be started. If the target
is 3Q (like for the standard Exstreamer
firmware) the value will be the ASCII
code of this two characters 0x5133.
The first character is the high byte.
Security
settings
97 B97 1 0 Bit 0: not used
Bit 1: disable factory defaults by
button (0=enabled)
Bit 2: disable remote update
functionality (0=enabled)
Bit 3: not used
Bit 4: not used
Bit 5: not used
Bit 6: not used
Bit 7: not used
See also “Reset Button Function” B276