Barix Instreamer User Manual Version 01.03
Page 7
7 Device Configuration
To enter the Barix Instreamer device configuration you can
log onto its local web server.
STEP 1
Open your Web Browser
STEP 2
Type in the IP address of the Barix Instreamer and hit enter
Example: 192.168.0.12
STEP 3
Click on the Config button
7.1 Configuration Overview
A INFO FRAME
This frame shows the Barix Instreamer’s MAC address and
the installed version of Firmware, Web application,
Bootloader and Setup.
B MENU FRAME
This frame shows the available menu icons.
A click on SETTINGS brings you to the settings page when
you are on the DEFAULTS, REBOOT or UPDATE page.
A click on HOME brings you to the device status page.
C SETTING TABS
This bar shows the available tabs within the settings menu.
D HELP FRAME
This frame shows the help to all settings and menus.
7.2 Network settings
Here you can configure the Barix Instreamer’s Static IP
address.
With this you can set a permanent IP address so that the
device does not have to get a new one upon power-up.
We recommend that you set a Static IP address.
IP Address
Enter the 4 values of the desired device IP address e.g.:
"0.0.0.0" for automatic discovery
(in this order: BOOTP, DHCP, IPzator, AutoIP.
See also section 10.4 Automatic discovery settings.)
"192.168.0.12" for an internal LAN
Netmask
Enter the 4 values of the desired Static IP e.g.:
"0.0.0.0" for a default Netmask depending on the used
IP Address.
"255.255.255.0" for a C class network
Gateway IP Address
Enter the 4 values of the desired Gateway IP address e.g.:
"0.0.0.0" for no Gateway
"192.168.0.1" for a Gateway in a LAN
Note: The Gateway has to be set only when connecting to
other devices over the WAN (through a router).
Use SonicIP
If set to “yes”, the Barix Instreamer will announce its IP
address over the audio output.
To store these settings click on Apply button.
The device will restart with the new settings.
A
B
D
C
Zobrazit stránku 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 22 23

Komentáře k této Příručce

Žádné komentáře

Simplicity Snow throwers user manuals

Starting on P

Click on an alphabet below to scroll to the full list of models starting with that letter

Models Document Type
P1732EX
Operator's Manual        Simplicity P1732EX Operator`s manual, 129 pages